Infusion Pump
- Intro
- Including 12 kinds working mode: Volume / Drop / Micro / Programme / DOSE Weight / Drug Lab. / Manual Bolus.
- A new generation of accuracy calibration technology, could directly enter the calibration value to fast calibrate of the machine batch, greatly enhance the efficiency of installation and maintenance.
- Builtin 500 kinds of drugs, covering the clinical use of the drug dose of 54 units on the library, and could be connect with the PC for edit; export & import.
- Comfort design with heater, Improve the experience of patients in low temperature infusion.
- Support changes the Rate, Time, Dose, VTBI & other important parameters during the infuse working.
- Advanced pressure detection technology, adjustable 20 level, and two option of units: mmHg / kPa.
- With the unique alarm: Prealarm of end infuse, Prealarm of high pressure block and etc. to meet the needs of special treatment
- IV set management, could add / remove / edit more than 40 kinds tubes.
- Powerful safety self-check function to ensure the pump working properly
- Product Code
SCEP002
- Specification
Function Option With Drug Lab. Without Drug Lab. Drug Lab. Built-in 500 kinds of drugs, covering the clinical use of the drug dose of 54 units on the library, and could be co nnect with the PC for edit; export & import. NONE Working Mode Rate/VTBI Time/VTBI. Rate/Time. Volume. Drop. Micro. Simple Rate. Programmable. DOSE Weight. Drug Lab. Auto Bolus. Manual Bolus. IV Set Open System for 10d/ml. 15d/ml. 20d/ml. 60d/ml (3.4mm – 4.5mm) IV Set management could add / remove ! edit more than 40 kinds tubes Accuracy Volume Mode : s ±3%, Drop Mode : s ±2% (after calibrate) Calibrate Automatic or manual calibration of infusion accuracy Rate Volume : 0.1ml/h ~ 1500ml/h Purge : 600ml/h Drop : ld/min ~ 400d/min VTBI 1 – 9999 ml or OFF Total Volume 1 0 – 9999.9 ml KVO Iml/h – 5ml/h Adjustable , Default : Iml/h Programmable Maximum 8 steps of different infuse rate ! time / VTBI BOLUS Manual Bolus : long Press the Bolus key to infuse and release to stop Auto Bolus : short press the Bolus key and set the VTBI & Rate Upper Pressure High ! Middle ! Low, 3 level, could off on the menu. Down Pressure 200mmHg – 1200mmHg, 20 level, live pressure display, mmHg & kPa two units Pre-Alarm Occlusion When the pressure in the tube goes up, it has the function of early warning Pre-Alarm Finish 1 min – 30 min, The alarm can be set ahead of VTBI Parameters Modify changes the Rate, Time, Dose, VTBI & other important parameters during the infuse working Keypad Locker Manual / Auto lock keyboard History Record Record 20000 infuse records, 10000 alarm records, can be downloaded to the computer to save & query Self-Test safety real time self-test function to ensure the pump working properly Bubble Detected by ultrasonic sensor with adjust setting 5 level, 50pL – 800pL Drop Sensor Infrared sensor to detect the number of drops, monitoring the status in case the empty bottles Alarm Bubble, Door open, Finish, Pause timeout Down Occlusion, Up Occlusion, Lower Battery or damage, Motor error, Incorrect IV Set-type, Pressure test failure, Motor failure, Abnormal drop rate, Heater failure and etc. 30 kinds safety monitoring alarm Light Tips 3 color light tips : Green for infuse working ; Orange for low level alarm (counting working) ; Red for high level alarm (pump stop). Voice Tips Compliance YY 0709-2009 medical standard, Alarm and key volume level adjustable, with Mute function , Monitor High brightness color LCD, Adjustable brightness Communication RS485 port connect with PC to update / download AC Power AC100V – 240V . 50Hz/60Hz , 25VA Battery Ni-MH battery, DC9.6V, 2000mAh (after full charged, could continue work more than 9 hours by 25ml/h rate) Battery power query Uve-time query battery life and battery charge status Class Class I, Type CF, IPX4 Installation For round and square pole , Horizontal / Vertical Dimension 2.0kg , 130mm x 120mmx 195mm Environment 5’C ~ 40’C; 20% ~ 90% humidity; 70kPa ~ 106kpa atmospheric Use Range For the patients with constant intravenous infusion of drugs